3.3 kW to 12.3 kW Hybrid Solar Inverter with Dual AC Output
De un vistazo
- Tipo de producto
- Hybrid Inverter
- Potencia nominal
- 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW
- Tipo de batería
- Lead-acid / lithium, charging profile set from the operation board
- Fase
- Monofásico
Homes that need to protect selected circuits during outages Available in 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW, lead-acid / lithium, charging profile set from the operation board battery support, monofásico.
- Seven models from 3.3 kW to 12.3 kW, single phase 230 V
- Second AC output rated at 30% of main output for load shedding
- Up to 2 MPPTs with 80-450 VDC tracking window
- 94% peak efficiency and 10 ms transfer time
Description
The LK-H2 adds a second AC output to the standard hybrid platform. The main output carries priority loads, while the second output can be shed automatically when battery state of charge or PV input falls below the configured threshold - useful where a site must keep refrigeration or lighting running but can afford to drop air conditioning.
Models run from 3.3 kW to 12.3 kW on a 24 V or 48 V battery bus, with up to two MPPTs on the larger units. The second output is rated at 30% of the main output. As with the rest of the range, grid-tied, off-grid and hybrid modes are selectable, and the unit supports lithium BMS communication and battery-less operation.
Product highlights
- Seven models from 3.3 kW to 12.3 kW, single phase 230 V
- Second AC output rated at 30% of main output for load shedding
- Up to 2 MPPTs with 80-450 VDC tracking window
- 94% peak efficiency and 10 ms transfer time
- Adjustable grid-feed current, output priority and charge priority
- Lithium BMS communication, battery-less operation supported
Technical specifications
| Serie | LK-H2 |
|---|---|
| Potencia nominal | 3.3 / 4.3 / 5.0 / 6.3 / 8.3 / 10.3 / 12.3 kW |
| Tipo de batería | Lead-acid / lithium, charging profile set from the operation board |
| Fase | Single phase |
| Potencia de segunda salida | 990 W / 1290 W / 1500 W / 1890 W / 2480 W / 3.09 kW / 3.69 kW |
| Potencia PV de entrada máx | 5.0 kW to 7.0 kW, or 4.5 kW x2 / 6.0 kW x2 |
| Rango de seguimiento MPPT | 40-450 VDC (24 V models) / 80-450 VDC (48 V models) |
| Tensión PV nominal | 240 VDC / 280 VDC |
| Tensión PV de circuito abierto máx | 500 VDC |
| Corriente PV de entrada máx | 18 A to 27 A, or 18 A x2 / 22 A x2 / 27 A x2 |
| Número de MPPT | 1 or 2, by model |
| Tensión de batería | 24 VDC (21-30 VDC) or 48 VDC (42-60 VDC) |
| Corriente de carga PV máx | 100 A to 200 A, by model |
| Corriente de carga AC máx | 80 A to 140 A, by model |
| Tensión de entrada AC | 230 VAC, selectable 220 / 230 / 240 VAC |
| Rango de entrada AC | 165-280 VAC or 120-280 VAC |
| Tensión de salida AC | 230 VAC, selectable 220 / 230 / 240 VAC, ±2% |
| Forma de onda de salida | Pure sine wave |
| Corriente de salida máx | 14.3 A to 53.5 A, by model |
| Rendimiento máximo | 94% |
| Tiempo de transferencia | 10 ms |
| Comunicación | RS485 / mobile app / WiFi monitoring, GPRS optional |
| Grado de protección | IP20 |
| Temperatura de servicio | −10 to 50 °C |
| Dimensiones (An×Al×Pr) | 325x275x102 mm to 630x540x130 mm, by model |
| Peso | 5.5 kg to 22 kg, by model |
Typical applications
- Homes that need to protect selected circuits during outages
- Small hotels and guesthouses with split critical and non-critical loads
- Shops running refrigeration plus lighting on one battery bank
- Offices with priority IT loads and deferrable HVAC
- Off-grid villas with generator-assisted charging